A Spectrum Protect administrator is configuring VTL on PowerProtect DD.
Which tape driver type should they select?
Questions 1 to 5 of the 54-question D-PDD-OE-01 bank, each with its correct answer, 4 with an explanation. This is page 1 of 11.
A Spectrum Protect administrator is configuring VTL on PowerProtect DD.
Which tape driver type should they select?
Following best practices for a PowerProtect DD CIFS environment, what is the recommended SESSTIMEOUT value in seconds?
SESSTIMEOUT valuefromthedefault45secondsto3600seconds.
A backup administrator is tasked with verifying the compression savings of a PowerProtect DD9900.
Which compression algorithm will they see enabled by default?
The gzfast compression algorithm is the default local compression method used on all DD6900, DD9400, and DD9900 appliances.
Which Dell PowerProtect Data Domain appliance requires a deep rack?
Comprehensive and Detailed Explanation From PowerProtect Data Domain Deploy
The Dell PowerProtect DD6410 has a deeper controller chassis than the other appliances listed, making rack depth a particularly important consideration during site preparation and physical deployment.
According to Dell's official DD6410 hardware specifications, the appliance measures approximately 837 mm (32.95 inches) from the mounting ears to the power supply surface, extending to approximately 873 mm (34.36 inches) at the PSU handles.
Dell US
By comparison, the DD9410, DD9910, and DD9910F controllers have a nominal chassis depth of approximately 724 mm (28.5 inches).
Dell UK+1
The additional chassis depth of the DD6410 must be accommodated by the rack structure, mounting rails, power distribution units, rear cabling, and service clearance.
Dell's DD6410 installation guidance specifies that supported third-party rack arrangements require at least 969 mm between the front mounting rail and rear-door features, excluding additional cable-dressing clearance.
Dell US
A technician must therefore validate the actual rack's usable depth rather than relying solely on its advertised external dimensions.
Options A, B, and D describe physically shorter controller designs. Although these appliances may also use deep racks depending on storage configuration and cable management, their controller chassis do not have the same depth requirement as the DD6410.
Therefore, DD6410 is the intended answer because its deeper chassis requires greater usable rack depth and rear clearance.
References: Dell PowerProtect Data Domain Deploy --- Pre-Deployment Check, Rack and Space Requirements; Dell PowerProtect DD 8.8 Hardware Features and Specifications --- DD6410 System Specifications; Dell DD6410 System Installation and Storage Expansion Guide --- Stab-In Sliding Rails and Rack Clearance.
An implementation engineer is at a customer site and is powering up the Dell PowerProtect Data Domain DD9910 with three DS600 expansion shelves.
What must be done before powering up the controller?
Comprehensive and Detailed Explanation From PowerProtect Data Domain Deploy
During the initial power-up of a Dell PowerProtect DD9910 with DS600 expansion shelves, the engineer must ensure that all connected disk shelves receive power before the controller starts.
The Dell DD9410 and DD9910 System Installation, Storage Expansion, and HA Upgrade Guide states:
Connect the power cables to power on the disk shelves before powering on the controller.
Dell Aruba
This startup sequence ensures that the SAS expansion enclosures and their storage devices are powered and available when the controller initializes its storage subsystem.
The DS600 shelves contain the physical disks used for Data Domain storage. Powering the shelves first allows the enclosure electronics, SAS expanders, and storage devices to initialize before DDOS begins hardware discovery.
Each DS600 shelf has two power supplies. Dell specifies connecting these supplies to redundant AC power sources to maintain availability if one power source fails.
Dell Ireland
Option B describes an important deployment verification task but does not establish the required storage power sequence. Option C concerns chassis identification rather than storage initialization. Option D provides a management access method but is not the required action before controller startup.
Following the correct power sequence reduces the likelihood of incomplete storage discovery and unnecessary hardware troubleshooting during initial configuration.
Therefore, the three DS600 expansion shelves must be powered before the DD9910 controller is powered on.
References: Dell PowerProtect Data Domain Deploy --- Deployment, Hardware Installation and Power-Up Procedures; Dell DD9410 and DD9910 System Installation, Storage Expansion, and HA Upgrade Guide --- Connecting Disk Shelf Power Cables and Connecting Controller Power Cables and Powering On.
Full exam access, validated answers, and unlimited practice with no download limits.